Facility services
The flow cytometry core facility offers analysis, sorting and cell counting services. It has two conventional sorters, the Aria IIu and SH800, two analyzers, the CytoFLEX LX and MACSQuant VYB, and one large particle sorter, the COPAS Select. It also houses a Moxi Z cell counter and QuadroMACS and miniMACS magnetic cell separation systems.

FACSAria IIu (Athena) - Cell Sorter (technician run)
-
5 lasers (355nm, 407nm, 488nm, 561nm and 640nm) w/ 14 fluorescent detectors
-
4 nozzle sizes (70um, 85um, 100um, and 130um)
-
Aerosol management system and temperature control
-
Tube (1.5, 5, and 15ml) and multi-well plate sorting
-
Aria IIu detector configuration (link to PDF) and sort questionnaire (link to PDF)
​

SH800 (Persephone) - Cell Sorter (training available)
-
2 lasers (488nm and 561nm) w/ 6 fluorescent detectors
-
3 nozzle sizes (70um, 100um, and 130um) - chip selection guide (link to PDF)
-
bioBUBBLE containment and temperature control
-
2-way tube and 1-way 96-well plate sorting
-
SH800 detector configuration (link to PDF) and sort form (link to online form)
​
Please include the following text in any publications using the SH800: "This equipment was supported in part, with support from the Indiana Clinical and Translational Sciences Institute, funded in part by Grant Number UL1 TR002529 from the National Institutes of Health, National Center for Advancing Translational Sciences, Clinical and Translational Sciences Award."

CytoFLEX LX (Apollo) - Cell Analyzer (training available)
-
4 lasers (405nm, 488nm, 561nm, 640nm) w/ 15 fluorescent detectors
- VSSC off the 405nm laser for small particle detection​
- Multi-well plate analysis
- Absolute counting
- CytoFLEX LX configuration (link to PDF)​
Please include the following text in any publications using the CytoFLEX LX: "This equipment was funded in part by the IU Office of Research through the Research Equipment Fund."

MACSQuant VYB (Mercury) - Cell Analyzer (training available)
-
Mobile (on a cart); MACSQuant VYB configuration (link to PDF)
-
3 lasers (405nm, 488nm, 561nm) w/ 8 fluorescent detectors
- FSC and SSC PMTs off the 561nm laser
- Single, multi-tube and 96-well plate sampling w/ chill racks for analysis at 4C
- Absolute counting
- Automated start-up and shut-down

COPAS Select (Achelous) - Large Particle Sorter (technician run)
-
1 laser (488nm) w/ 3 fluorescent detectors
-
500 micron flow cell to collect particles from 20-350 micron in diameter
-
1-way sorting into petri dish or multi-well plate
-
Advanced Acquisition Package (AAP) for increased sensitivity and faster analysis
-
​Union Biometrica website (link)

Moxi Z - Cell Counter & Sizer (training available)
-
Reports both cell counts and concentrations of a cell population
-
Measures size distribution of the cell population
-
Size range
-
M-type cartridge = 4-30-micron
-
S-type cartridge = 3-26-micron
-

Quadro and mini-MACS (available for check-out)
-
Magnet-based gentle cell separation
-
Used in conjunction with Miltenyi Biotec's LD and LS columns